Perancangan ulang surface condenser PLTU 100 MW
Penerbit : FTI - Usakti
Kota Terbit : Jakarta
Tahun Terbit : 2009
Pembimbing 1 : Bambang Teguh Prasetyo
Subyek : Mechanical engineering
Kata Kunci : redesign, surface condenser, PLTU, 100 MW
Status Posting : Published
Status : Tidak Lengkap
No. | Nama File | Hal. | Link |
---|---|---|---|
1. | 2009_TA_STM_06103038_Halaman-Judul.pdf | 11 | |
2. | 2009_TA_STM_06103038_Lembar-Pengesahan.pdf | 3 | |
3. | 2009_TA_STM_06103038_Bab-1_Pendahuluan.pdf | 3 | |
4. | 2009_TA_STM_06103038_Bab-2_Landasan-Teori.pdf |
|
|
5. | 2009_TA_STM_06103038_Bab-3_Perancangan-Panas-dan-Mekanikal.pdf |
|
|
6. | 2009_TA_STM_06103038_Bab-4_Hasil-Perhitungan-dan-Rancangan.pdf |
|
|
7. | 2009_TA_STM_06103038_Bab-5_Kesimpulan-dan-Saran.pdf |
|
|
8. | 2009_TA_STM_06103038_Daftar-Pustaka.pdf |
|
|
9. | 2009_TA_STM_06103038_Lampiran.pdf | 21 |
P Perancangan ulang surface condenser PLTU (Pembangkit Listrik Tenaga Uap) 100MW telah dilakukan. Di dalam suatu instalasi pembangkit listrik tenaga uap diperlukan suatu komponen yang membuat operasi siklus lebih efisien. Salah satu komponen tersebut adalah surface condenser. Tujuan utama dari surface condeser pada suatu instalasi pembangkit adalah untuk mengkondensasi uap keluar dan turbin sehingga dapat menyelamatkan sejumlah besar air penambah dan menciptakan tekanan keluar turbin rendah sehingga effisien siklus power plant akan naik. Sampai saat ini, penguasaaan dibidang surface condenser masih dirasa kurang, maka dalam Tugas Akhir ini penulis mencoba merancang sebuah surface condenser dengan satu pass divided. Dengan metode perhitungan yang digunakan untuk merancang surface condenser dengan satu pass divided ini adalah metode LMTD.Metode LMTD adalah metode yang diterapkan pada segmen-segmen sepanjang surface condenser. Dengan demikian sifat yang perlu diperhatikan adalah perbedaan temperatur rata-rata dan air pendingin. Besar kecilnya kesalahan perhitungan jumlah tube sangat bergantung pada beda suhu air pendinginan yang ditentukan. Hasil perhitungan kemudian dibandingkan dengan hasil data yang sudah ada. Dari hasil perbandingkan jumlah tube menunjukkan bahwa metode LMTD ini dapat digunakan untuk menghitung surface condenser, karena persentase kesalahannya hanya 2,56 %.
T The redesign of the 100MW Steam Power Plant (PLTU) surface condenser has been carried out. In a steam power plant installation, a component is needed to make the cycle operation more efficient. One of these components is the surface condenser. The main purpose of the surface condenser in a power plant installation is to condense the steam exiting the turbine so that it can save a large amount of additional water and create a low turbine outlet pressure so that the power plant cycle efficiency will increase. Until now, mastery in the field of surface condensers is still considered lacking, so in this Final Project the author tries to design a surface condenser with a single pass divided. The calculation method used to design this single pass divided surface condenser is the LMTD method. The LMTD method is a method applied to segments along the surface condenser. Thus, the properties that need to be considered are the average temperature difference and the cooling water. The size of the error in calculating the number of tubes depends greatly on the difference in the specified cooling water temperature. The calculation results are then compared with the results of existing data. The results of the comparison of the number of tubes show that the LMTD method can be used to calculate the surface condenser, because the percentage error is only 2.56%.