DETAIL KOLEKSI

Perancangan ulang low pressure heater PLTU 200mw


Oleh : Shafarudin Shafar

Info Katalog

Penerbit : FTI - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2011

Pembimbing 1 : Bambang Teguh Prasetyo

Subyek : Power - plant - Installation;Mechanical engineering

Kata Kunci : redesign, low pressure heater, PLTU, 200mw

Status Posting : Published

Status : Tidak Lengkap


File Repositori
No. Nama File Hal. Link
1. 2011_TA_STM_06105034_Halaman-Judul.pdf 13
2. 2011_TA_STM_06105034_Lembar-Pengesahan.pdf 2
3. 2011_TA_STM_06105034_Bab_1_Pendahuluan.pdf 3
4. 2011_TA_STM_06105034_Bab_2_Landasan-Teori.pdf
5. 2011_TA_STM_06105034_Bab_3_Perancangan-Panas-Dan-Mekanikal.pdf
6. 2011_TA_STM_06105034_Bab_4_Hasil-Perhitungan-Rancangan.pdf
7. 2011_TA_STM_06105034_Bab_5_Kesimpulan.pdf 1
8. 2011_TA_STM_06105034_Daftar-Pustaka.pdf 1
9. 2011_TA_STM_06105034_Lampiran.pdf

P Perancangan ulang low pressure heater PLTU (Pembangkit Listrik Tenaga Uap) 200MW telah dilakukan. Di dalam suatu instalasi pembangkit listrik tenaga uap diperlukan suatu komponen yang membuat operasi siklus lebih efisien. Salah satu komponen tersebut adalah closed feed water heater. Tujuan utama dari closed feed water heater pada suatu instalasi pembangkit adalah untuk menaikan suhu air sebelum masuk ke economizer atau steam drum. Sampai saat ini, penguasaaan dibidang closed feed water heater masih dirasa kurang, maka dalam Tugas Akhir ini penulis mencoba merancang sebuah closed feed water heater jenis shell and tube. Dengan metode perhitungan yang digunakan untuk merancang closed feed water heater jenis shell and tube ini ad metode T-H Diagram.Metode T-H Diagram adalah metode LMTD kan pada segmen-segmen sepanjang . . close feed water heater an demikian' sifat-si fisik yang dipergunakanadalah sifat-sifat fisik pada tempe pada se ap segmen, sehingga menberikan ketelitian dalam pengambilan harga sifat-sifat fisik. Besar kecilnya kesalahan sangat bergantung pada lebar segmen yang diambil pada perhitungan. Hasil perhitungan kemudian dibandingkan dengan hasil data yang sudah ada. Dari basil perbandingkan panjang tube menunjukkan bahwa metode T - H diagram ini dapat digunakan untuk menghitung closed feed water heater, karena persentase kesalahannya hanya 0,08 %.

A A redesign of the low-pressure heater of a 200MW Steam Power Plant (PLTU) has been carried out. A steam power plant requires a component to make the cycle more efficient. One such component is the closed feed water heater. The primary purpose of a closed feed water heater in a power plant is to increase the temperature of the water before it enters the economizer or steam drum. Currently, expertise in closed feed water heaters is still lacking, so in this final project, the author attempts to design a shell and tube closed feed water heater. The calculation method used to design this shell and tube closed feed water heater is the T-H Diagram method. The T-H Diagram method is a LMTD method for segments along the length. The physical properties used are the physical properties of the tempe in each segment, thus providing accuracy in calculating physical properties. The magnitude of the error depends heavily on the width of the segment taken in the calculation. The calculation results are then compared with existing data. From the results of the comparison of tube lengths, it shows that the T - H diagram method can be used to calculate closed feed water heaters, because the error percentage is only 0.08%.