Analisis pengguna energi pada Gedung Hery Hartanto Kmapus A Universitas Trisakti
Penerbit : FTI - Usakti
Kota Terbit : Jakarta
Tahun Terbit : 2013
Pembimbing 1 : Ishak Kasim
Subyek : Electric power transmission;Electrical engineering
Kata Kunci : energy users, Hery Hartanto Building, Campus A, Trisakti University
Status Posting : Published
Status : Tidak Lengkap
| No. | Nama File | Hal. | Link |
|---|---|---|---|
| 1. | 2013_TA_STE_06208016_Halaman-Judul.pdf | 16 | |
| 2. | 2013_TA_STE_06208016_Lembar-Penesahan.pdf | 2 | |
| 3. | 2013_TA_STE_06208016_Bab-1-Pendahuluan.pdf | 4 | |
| 4. | 2013_TA_STE_06208016_Bab-2-Tinjauan-Pustaka.pdf |
|
|
| 5. | 2013_TA_STE_06208016_Bab-3-Metodologi-Penelitian.pdf |
|
|
| 6. | 2013_TA_STE_06208016_Bab-4-Analisis-Hasil-dan-Pembahasan.pdf |
|
|
| 7. | 2013_TA_STE_06208016_Bab-5-Kesimpulan-dan-Saran.pdf | ||
| 8. | 2013_TA_STE_06208016_Daftar-Pustaka.pdf | 1 | |
| 9. | 2013_TA_STE_06208016_Lampiran.pdf |
|
K Kualitas daya listrik yang baik sangat diperlukan pada industri, perkantoran maupun sistem pendidikan. Standard kualitas daya listrik yang perlu diperhatikan dalam menentukan baik atau tidaknya kualitas daya listrik, antara lain : Tegangan, Frekuensi, Faktor daya (cos phi) dan Distorsi harmonisa. Pada penelitian ini standard yang digunakan adalah SPLN 1, 1995, SN1 6196, 2000 dan STD IEEE 519-1992 dan pengukuran dilakukan pada Gedung Hery Hartanto Kampus A Universitas Trisakti, Jakarta. Pengukuran dilakukan dengan menggunakan alat ukur Hioki 3286-20 Digital Clamp On Power Hi Tester, alat ini dapat mengukur Tegangan, Frekuensi, Faktor daya (cos phi) dan Distorsi harmonisa. Data yang diukur dengan menggunakan Hioki 3286-20 Digital Clamp On Power Hi Tester, akan dibandingkan dengan standard kualitas daya yang sesuai oleh standard SPLN 1, 1995 dan STD IEEE 519-1992. Untuk Tegangan 380+10%, THD-V < 5%, Frekuensi 50hz, THD-I < 8%, Faktor Daya > 0.85 — 1. Data yang diperoleh kemudian dibandingkan dengan standard yang diijinkan. Dari basil analisis yang sudah diukur dapat disimpulkan bahwa kualitas daya dari sup lai listrik di Gedung Hery Hartanto Kampus A Universitas Trisakti memenuhi syarat yang diijinkan oleh SPLN.
G Good electrical power quality is essential for industry, offices, and education systems. Electrical power quality standards that need to be considered in determining whether the electrical power quality is good or not include: Voltage, Frequency, Power factor (cos phi) and Harmonic distortion. In this study, the standards used are SPLN 1, 1995, SN1 6196, 2000 and STD IEEE 519-1992 and measurements were carried out at the Hery Hartanto Building, Campus A, Trisakti University, Jakarta. Measurements were carried out using the Hioki 3286-20 Digital Clamp On Power Hi Tester, this tool can measure Voltage, Frequency, Power factor (cos phi) and Harmonic distortion. Data measured using the Hioki 3286-20 Digital Clamp On Power Hi Tester will be compared with the appropriate power quality standards by the SPLN 1, 1995 and STD IEEE 519-1992 standards. For Voltage 380+10%, THD-V < 5%, Frequency 50hz, THD-I < 8%, Power Factor > 0.85 — 1. The data obtained were then compared with the permitted standards. From the results of the analysis that have been measured, it can be concluded that the power quality of the electricity supply in the Hery Hartanto Building, Campus A, Trisakti University meets the requirements permitted by SPLN.