DETAIL KOLEKSI

Perancangan ulang high pressure heater PLTU 100MW


Oleh : Handrik

Info Katalog

Penerbit : FTI - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2008

Pembimbing 1 : Bambang Teguh Prasetyo

Subyek : Electrical energy;Electrical engineering

Kata Kunci : diagram, metode LMTD, closed feed water, perhitungan

Status Posting : Published

Status : Tidak Lengkap


File Repositori
No. Nama File Hal. Link
1. 2008_TA_STM_06103001_Halaman-Judul.pdf
2. 2008_TA_STM_06103001_Lembar-Pengesahan.pdf
3. 2008_TA_STM_06103001_Bab-1_Pendahuluan.pdf 3
4. 2008_TA_STM_06103001_Bab-2_Tinjauan-Pustaka.pdf
5. 2008_TA_STM_06103001_Bab-3_Metodologi-Penelitian.pdf
6. 2008_TA_STM_06103001_Bab-4_Analisis-Hasil-dan-Pembahasan.pdf
7. 2008_TA_STM_06103001_Bab-5_Kesimpulan-dan-Saran.pdf
8. 2008_TA_STM_06103001_Daftar-Pustaka.pdf

P Perancangan ulang high pressure heater PLTU (Pembangkit Listrik Tenaga Uap) lOOMW telah dilakuakan . Di dalam suatu instalasi pembangkit listrik tenaga uap diperlukan suatu komponen yang membuat operasi siklus lebih efisien. Salah satu komponen tersebut adalah closed feed water heater. Tujuan utama dari closed feed water heater pada suatu instalasi pembangkit adalah untuk menaikan suhu air sebelum masuk ke economizer atau steam drum.Sampai saat ini, penguasaaan dibidang closed feed water heater masih dirasa kurang, makadalam Tugas Akhir ini penulis mencoba merancang sebuah closed feed waterheater jenis shell and tube. Dengan metode perhitungan yang digunakan untuk merancang closed feed water heater jenis shell and tube ini adalah metode T-H Diagram.Metode T-H Diagram adalah metode LMTD yang diterapkan pada segmen-segmen sepanjang close feed water heater. Dengan demikian sifat-sifat fisik yang dipergunakan adalah sifat-sifat fisik pada temperatur rata-rata pada setiap segmen, sehingga menberikan ketelitian dalam pengambilan harga sifat­ sifat fisik. Besar kecilnya kesalahan sangat bergantung pada lebar segmen yang diambil pada perhitungan. Hasil perhitungan kemudian dibandingkan dengan hasil data yang sudah ada. Dari hasil perbandingkan panjang tube menunjukkan bahwa metode T - H diagram ini dapat digunakan untuk menghitung closed feed water heater, karena persentase kesalahannya hanya 0,77 %.

R Redesign of high pressure heater for 1OOMW steam power plant has been done. In the steam power plant installation this component that providing more efficient cycle operation is needed . One of the component is closed feed water heater. The purposes of closed feed water heater is to increase the feed water temperature before entered economizer or steam drum. Until now a days , the mastery in design at closed feed water heater is still limited, so in this thesis, present a design of closed feed water heater typically, is shell and tube. Thermal design method using in this study, is Temperature-Enthalpy (T-H) iliagram method . T-H diagram method is a logarithmic mean temperature difference (LMTD) method were implemented on each segments, a long the length of the heater. Thereby, physical properties that were used are physical properties in average temperature on each segments, this method reduce the significant error in design. The error is dependent on segment ilimension. The design result, then is compared with available data. From the comparison of tube length the results was shown that T-H Diagram method is applicable to thermal calculation of feed water heater, because the percent of error is around 0.77%.

Bagaimana Anda menilai Koleksi ini ?